 | English - 0,38MB | Article 2008-11-19 | |
 |
Doc No: 9AKK104295D3107 Document kind: Article Language: English Size: 0,38MB Expected download time: 55 seconds (speed: 56Kb) Published: 2008-11-19 Revision: - File type: pdf Summary: 5 page article from the ABB Technolgy magazine "ABB Review - Special Report "Dancing with the dragon" 2008 II (Authors: Walter Holaus, Fredi Stucki):
China is in urgent need of electrical power. Huge power plants are built all over the country and the enormous flow of electrical power to the large megacities has to
cross several thousand kilometers from the source to the end user.
At those dimensions, losses of the power lines can be significant. The State Grid Corporation of China (SGCC) is thus aiming for 1,100 kV as the voltage level for AC transmission to keep losses as low as possible, a step into a new area of electrical grids.
ABB, together with its partners and suppliers, has developed the heart of such a system – a gas-insulated switchgear design – that could pass all the tests with this groundbreaking technology.
|
 | English - 1,16MB | Article 2005-09-23 | |
 |
Doc No: PE-596-EC-0-05-01 Document kind: Article Language: English Size: 1,16MB Expected download time: 2 minutes (speed: 56Kb) Published: 2005-09-23 Revision: - File type: pdf Summary: 10-page article recommended and approved by the IEEE. Manuscript published 1997
|
 | English, German - 1,74MB | Article 2009-07-01 | |
 |
Doc No: 9AKK104295D6144 Document kind: Article Language: English, German Size: 1,74MB Expected download time: 4 minutes (speed: 56Kb) Published: 2009-07-01 Revision: - File type: pdf Summary: 4 page article from VGB PowerTech Magazin 6/2009, from Dieter Braun, Giosafat Cavaliere, Kurt Dahinden and Martin Lakner. (Kurzfassung in Deutsch)
|
 | English - 0,55MB | Article 2005-09-23 | |
 |
Doc No: CEPSI2000-001 Document kind: Article Language: English Size: 0,55MB Expected download time: 1 minutes (speed: 56Kb) Published: 2005-09-23 Revision: - File type: pdf Summary: 12 page article from Mark Seelig, speech held on CEPSI 2000, Philippines: Today, the use of generator circuit-breakers for the switching of generators at their terminal voltage is widespread because they offer many advantages when compared to the unit connection such as lower first costs, simplified operational procedures and better fault protection.
|
 | English - 1,36MB | Article 2005-09-23 | |
 |
Doc No: 13-204 Document kind: Article Language: English Size: 1,36MB Expected download time: 3 minutes (speed: 56Kb) Published: 2005-09-23 Revision: - File type: pdf Summary: 10-page article from CIGRE in 1994
|
 | English - 0,35MB | Article 2008-11-19 | |
 |
Doc No: 9AKK104295D3109 Document kind: Article Language: English Size: 0,35MB Expected download time: 51 seconds (speed: 56Kb) Published: 2008-11-19 Revision: - File type: pdf Summary: 4 page article from the ABB Technolgy magazine "ABB Review - Special Report "Dancing with the dragon" 2008 II (Authors: Daniel Chartouni, Martin Lakner, Giosafat Cavaliere): A generator circuit breaker (GCB) is a core component of a power plant, protecting both the generator and the power transformer. ABB’s current breaker portfolio includes breakers with rated nominal currents ranging from 6300 A to over 50,000 A. HECS breakers are designed for nominal currents up to 18,000 A. However, a side effect of these large currents is heat dissipation in the device, which must be limited if other system components are to remain within their rated temperature tolerances. Natural cooling limits the rated
nominal current and therefore many of today’s GCBs employ forced cooling methods to increase nominal current levels. However, these “forced” coolers also limit nominal current capability.
To increase GCB nominal currents, an innovative cooling method was required to meet the ever-increasing demand for lighter, cheaper and more powerful devices. Using socalled heat pipes to achieve efficient heat transfer, not only have they developed two products that are lighter and more robust than previous versions, but GCB performance has increased by over 25 percent!
|
 | English - 1,57MB | Article 2005-09-23 | |
 |
Doc No: ETEP Vol. 6 Document kind: Article Language: English Size: 1,57MB Expected download time: 3 minutes (speed: 56Kb) Published: 2005-09-23 Revision: - File type: pdf Summary: 7-page article published from ETEP in 1996
|
 | English - 1,46MB | Article 2005-08-02 | |
 |
Doc No: 200203-M785 Document kind: Article Language: English Size: 1,46MB Expected download time: 3 minutes (speed: 56Kb) Published: 2005-08-02 Revision: - File type: pdf Summary: 7-page article from ABB Technology magazin "ABB Review 2002/3 (Lukas Zehnder, Jochen Kiefer, Dieter Braun, Thomas Schoenemann)
Generator circuit-breakers are the ‘big boys’ of the breaker world; they have to be. A fault of up to 200 kA
somewhere in the field is bad enough, but close to a generator it can lead to an event of literally seismic
proportions – the fault current can be of such a magnitude that the induced magnetic forces cause solid steel shafts to bend and crash.
ABB HEC 7/8 SF6 breakers are designed for this demanding task. They can handle anything even the world’s biggest power stations can throw at them. But just how do you break such a huge current so close to the generator? And how can the breaker effectively deal with the arc that is produced?
|
 | English - 1,23MB | Brochure 2005-09-20 | |
 |
Doc No: PTPGOV0705 Document kind: Brochure Language: English Size: 1,23MB Expected download time: 2 minutes (speed: 56Kb) Published: 2005-09-20 Revision: - File type: pdf Summary: 10 pages general brochure about the offerings for the Power Generation Industry. "ABB offers expertise in four Key Areas:
(1) Electrical Balance of Plant, (2) Motors and Drives, (3) Instrumentation and (4) Controls"
|
 | English - 0,23MB | Brochure 2008-01-28 | |
 |
Doc No: 1HC0015509Document kind: BrochureLanguage: EnglishSize: 0,23MBPart: 1-1 - View associated documentsExpected download time: 33 seconds (speed: 56Kb)Published: 2008-01-28Revision: ABFile type: pdfSummary: Brochure for Generator Circuit Breaker After Sales Service
|
 | English - 0,17MB | Brochure 2008-08-15 | |
 |
Doc No: 1HC0015509Document kind: BrochureLanguage: EnglishSize: 0,17MBPart: 2-2 - View associated documentsExpected download time: 24 seconds (speed: 56Kb)Published: 2008-08-15Revision: ABFile type: pdfSummary: Brochure for Generator Circuit Breaker After Sales Service
|
 | English - 0,53MB | Brochure 2010-06-09 | |
 |
Doc No: 1HC0015509E12 Document kind: Brochure Language: English Size: 0,53MB Expected download time: 1 minutes (speed: 56Kb) Published: 2010-06-09 Revision: AB File type: pdf Summary: 4 page brochure
|
 | English - 0,53MB | Brochure 2010-06-09 | |
 |
Doc No: 1HC0015509E12 Document kind: Brochure Language: English Size: 0,53MB Expected download time: 1 minutes (speed: 56Kb) Published: 2010-06-09 Revision: AB File type: pdf Summary: 4 page brochure
|
 | English - 0,52MB | Brochure 2010-06-09 | |
 |
Doc No: 1HC0070730 Document kind: Brochure Language: English Size: 0,52MB Expected download time: 1 minutes (speed: 56Kb) Published: 2010-06-09 Revision: AA File type: pdf Summary: 5-page product brochure
|
 | English - 0,52MB | Brochure 2010-06-09 | |
 |
Doc No: 1HC0070730 Document kind: Brochure Language: English Size: 0,52MB Expected download time: 1 minutes (speed: 56Kb) Published: 2010-06-09 Revision: AA File type: pdf Summary: 5-page product brochure
|
 | English - 3,44MB | Brochure 2010-06-09 | |
 |
Doc No: 1HC0015509E13 Document kind: Brochure Language: English Size: 3,44MB Expected download time: 8 minutes (speed: 56Kb) Published: 2010-06-09 Revision: AA File type: pdf Summary: 10-page product brochure
|
 | English - 3,44MB | Brochure 2010-06-09 | |
 |
Doc No: 1HC0015509E13 Document kind: Brochure Language: English Size: 3,44MB Expected download time: 8 minutes (speed: 56Kb) Published: 2010-06-09 Revision: AA File type: pdf Summary: 10-page product brochure
|
 | English - 0,96MB | Brochure 2010-06-07 | |
 |
Doc No: 1HC0072302 Document kind: Brochure Language: English Size: 0,96MB Expected download time: 2 minutes (speed: 56Kb) Published: 2010-06-07 Revision: AA File type: pdf Summary: 6-page product brochure
|
 | English - 0,96MB | Brochure 2010-06-07 | |
 |
Doc No: 1HC0072302 Document kind: Brochure Language: English Size: 0,96MB Expected download time: 2 minutes (speed: 56Kb) Published: 2010-06-07 Revision: AA File type: pdf Summary: 6-page product brochure
|
 | English - 1,17MB | Brochure 2010-06-09 | |
 |
Doc No: 1HC0067697 Document kind: Brochure Language: English Size: 1,17MB Expected download time: 2 minutes (speed: 56Kb) Published: 2010-06-09 Revision: AB File type: pdf Summary: 5-page product brochure
|
| Prev 1 2 Next | | |